Thank you for considering Wems Electronics part number WE-3590, a component we stock that is further identified by the NSN 5950-01-330-8659 and product description “Transformer Power.” This item is currently available for purchase on our website today, and you can obtain a tailored quote at any time by completing the form on this page. To help us provide the best solution, please include critical details like your quantity requirements, target pricing, and delivery preferences within the submitted request. Once we receive your form, our team will promptly review provided information and respond with a quote that aligns with your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number WE-3590, we encourage you to explore other offerings we carry from Wems Electronics that have been produced under CAGE Code 26543, as well as similar products classified under FSC 5950 Coils and Transformers that may suit your projects. We can help you obtain pricing on all items that you are interested in, securing the most optimal solution for you. We are also happy to discuss any requirements that you may have, presenting specialized options for many restrictions and needs alike. With our services in mind, please submit your request for part number WE-3590 today and discover why Marine Defence Parts is a trusted partner for naval and defense procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-330-8659 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013308659 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
841331-1 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ABHP | OVERALL LENGTH | 3.150 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.140 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.590 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.610 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.775 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.600 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 16.7 KILOHERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 20.93 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 41.85 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TURRET |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.12 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 150.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 20.93 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | TERMINAL 17 IS INTERNALLY CONNECTED TO TERMINAL 3; TERMINAL 18 IS INTERNALLY CONNECTED TO TERMINAL 1; TERMINAL 19 IS INTERNALLY CONNECTED TO TERMINAL 2; TERMINAL 13 AND 14 ARE INTERNALLY CONNECTED DUMMY TERMINALS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |