Thank you for considering Northrop Grumman Systems Corporation part number 159852, a component we stock that is further identified by the NSN 5950-01-339-6683 and product description “Coil Electrical.” This item is currently available for purchase on our website today, and you can obtain a tailored quote at any time by completing the form on this page. To help us provide the best solution, please include critical details like your quantity requirements, target pricing, and delivery preferences within the submitted request. Once we receive your form, our team will promptly review provided information and respond with a quote that aligns with your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 159852, we encourage you to explore other offerings we carry from Northrop Grumman Systems Corporation that have been produced under CAGE Code 06481, as well as similar products classified under FSC 5950 Coils and Transformers that may suit your projects. We can help you obtain pricing on all items that you are interested in, securing the most optimal solution for you. We are also happy to discuss any requirements that you may have, presenting specialized options for many restrictions and needs alike. With our services in mind, please submit your request for part number 159852 today and discover why Marine Defence Parts is a trusted partner for naval and defense procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-339-6683 Item PartTypeName: COIL,ELECTRICAL | 5950 | 013396683 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3C500 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHY | TURN QUANTITY | 16 SINGLE COMPONENT 1ST WINDING24 SINGLE COMPONENT 2ND WINDING |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 45413-142608 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.088 INCHES MINIMUM SINGLE GROUP |
ACYV | INDUCTANCE RATING | 15.00 MICROHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING32.00 MICROHENRIES NOMINAL SINGLE COMPONENT 2ND WINDING |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZR | CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
ADAQ | BODY LENGTH | 0.410 INCHES MINIMUM AND 0.420 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.793 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING AND WINDING TURNS SINGLE COMPONENT ALL WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.03196 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 1ST WINDING0.02010 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 2ND WINDING |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING |
CWJS | WINDING OPERATING VOLTAGE | 50.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |
CRGS | DC RESISTANCE RATING IN OHMS | 0.010 SINGLE COMPONENT 1ST WINDING0.036 SINGLE COMPONENT 2ND WINDING |