Thank you for considering Lockheed Martin Corporation part number 77C707862P001, a component we stock that is further identified by the NSN 5950-00-941-5962 and product description “Transformer Power.” This item is currently available for purchase on our website today, and you can obtain a tailored quote at any time by completing the form on this page. To help us provide the best solution, please include critical details like your quantity requirements, target pricing, and delivery preferences within the submitted request. Once we receive your form, our team will promptly review provided information and respond with a quote that aligns with your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 77C707862P001, we encourage you to explore other offerings we carry from Lockheed Martin Corporation that have been produced under CAGE Code 03538, as well as similar products classified under FSC 5950 Coils and Transformers that may suit your projects. We can help you obtain pricing on all items that you are interested in, securing the most optimal solution for you. We are also happy to discuss any requirements that you may have, presenting specialized options for many restrictions and needs alike. With our services in mind, please submit your request for part number 77C707862P001 today and discover why Marine Defence Parts is a trusted partner for naval and defense procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-941-5962 Item PartTypeName: TRANSFORMER,POWER | 5950 | 009415962 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
77C707862P001 | 6 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.938 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.375 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.312 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 8.35 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 59.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB,SOLDER LUG |