Thank you for considering Keytronics Inc part number K5331, a component we stock that is further identified by the NSN 5950-00-237-1073 and product description “Transformer Power.” This item is currently available for purchase on our website today, and you can obtain a tailored quote at any time by completing the form on this page. To help us provide the best solution, please include critical details like your quantity requirements, target pricing, and delivery preferences within the submitted request. Once we receive your form, our team will promptly review provided information and respond with a quote that aligns with your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number K5331, we encourage you to explore other offerings we carry from Keytronics Inc that have been produced under CAGE Code 51181, as well as similar products classified under FSC 5950 Coils and Transformers that may suit your projects. We can help you obtain pricing on all items that you are interested in, securing the most optimal solution for you. We are also happy to discuss any requirements that you may have, presenting specialized options for many restrictions and needs alike. With our services in mind, please submit your request for part number K5331 today and discover why Marine Defence Parts is a trusted partner for naval and defense procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-237-1073 Item PartTypeName: TRANSFORMER,POWER | 5950 | 002371073 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
NES-4107 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.120 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.245 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.875 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ADAQ | BODY LENGTH | 6.250 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 24.5 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY89.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY28.00 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY28.00 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND NINE SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 18876-10668614 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 37 TAB,SOLDER LUG |