Thank you for considering Chromalox Corp part number 049197-001, a component we stock that is further identified by the NSN 5930-00-602-1599 and product description “Switch Thermostatic.” This item is currently available for purchase on our website today, and you can obtain a tailored quote at any time by completing the form on this page. To help us provide the best solution, please include critical details like your quantity requirements, target pricing, and delivery preferences within the submitted request. Once we receive your form, our team will promptly review provided information and respond with a quote that aligns with your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 049197-001, we encourage you to explore other offerings we carry from Chromalox Corp that have been produced under CAGE Code 65586, as well as similar products classified under FSC 5930 Switches that may suit your projects. We can help you obtain pricing on all items that you are interested in, securing the most optimal solution for you. We are also happy to discuss any requirements that you may have, presenting specialized options for many restrictions and needs alike. With our services in mind, please submit your request for part number 049197-001 today and discover why Marine Defence Parts is a trusted partner for naval and defense procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-602-1599 Item Description: SWITCH,THERMOSTATIC | 5930 | 006021599 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
049197-001 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQGB | Contact Action Stimulus | DECREASE |
ABHP | Overall Length | 2.1875 INCHES NOMINAL |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE |
AXGY | Mounting Method | THREADED HOLE AND |
AEVT | Capillary Tube Length | 15.0 INCHES NOMINAL |
AAJD | Thread Class | 2B SINGLE PRESSURE CONNECTION |
CTYM | Contact Adjustment Range | 55.00 TO 105.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | Contact Adjustment Type | EXTERNAL ACTUATION POINT DIAL |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE |
ABMK | Overall Width | 1.250 INCHES NOMINAL |
CTYX | Contact Stimulus Rating | 3.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | Contact Voltage Rating In Volts | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
STYL | Style Designator | RECTANGULAR |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
AXGY | Mounting Method | UNTHREADED HOLE |
CTYC | Contact Adjustability | DEACTUATION POINT NOT ADJUSTABLE AND |
CTZB | Contact Voltage Rating In Volts | 277.0 AC AT SEA LEVEL FIRST VOLTAGE |
AEJN | Distance Between Mounting Facility Centers | 1.750 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES SINGLE PRESSURE CONNECTION |
ADAQ | Body Length | 1.4375 INCHES NOMINAL |
AEVU | Bulb Length | 5.500 INCHES NOMINAL |
ABKW | Overall Height | 2.6875 INCHES NOMINAL |
THSD | Thread Series Designator | UNC SINGLE PRESSURE CONNECTION |
AKBY | Temp Sensing Element Type | CAPILLARY TUBE-BULB |
CTHF | Contact Load Current Rating | 22.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | Contact Load Current Rating | 25.0 AMPERES RESISTIVE LOAD AND |
CTHF | Contact Load Current Rating | 10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CMLP | Thread Quantity Per Inch | 32 SINGLE PRESSURE CONNECTION |
AEJN | Distance Between Mounting Facility Centers | 1.3125 INCHES MINIMUM AND |
CSCF | Terminal Type | WIRE LEAD |
MEDA | Media For Which Designed | GAS |
AEVV | Bulb Diameter | 0.375 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.4375 INCHES NOMINAL |