Thank you for considering At And T Corp part number 5883986-1, a component we stock that is further identified by the NSN 5930-01-312-4638 and product description “Switch Thermostatic.” This item is currently available for purchase on our website today, and you can obtain a tailored quote at any time by completing the form on this page. To help us provide the best solution, please include critical details like your quantity requirements, target pricing, and delivery preferences within the submitted request. Once we receive your form, our team will promptly review provided information and respond with a quote that aligns with your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 5883986-1, we encourage you to explore other offerings we carry from At And T Corp that have been produced under CAGE Code 92663, as well as similar products classified under FSC 5930 Switches that may suit your projects. We can help you obtain pricing on all items that you are interested in, securing the most optimal solution for you. We are also happy to discuss any requirements that you may have, presenting specialized options for many restrictions and needs alike. With our services in mind, please submit your request for part number 5883986-1 today and discover why Marine Defence Parts is a trusted partner for naval and defense procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-312-4638 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 013124638 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5883986-2 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 1.040 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.360 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.660 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES MINIMUM AND 0.999 INCHES MAXIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AWTN | OPERATING TEMP RATING | -10.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND SLOT |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.5 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 130.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 125.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 128.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
FEAT | SPECIAL FEATURES | TERMINALS 32.120 IN. LG |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | DISC |