MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.590 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 5.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 15.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.552 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAU | BODY HEIGHT | 4.750 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 126.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 132.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |