MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 3.130 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ADAV | OVERALL DIAMETER | 2.500 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.168 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.175 INCHES MAXIMUM SINGLE MOUNTING FACILITY" |
AGAV | END ITEM IDENTIFICATION | ALOFTS SONAR SYSTEM, MODEL 980 (V1)" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNA | WINDING DC RESISTANCE RATING | 180.0 OHMS MINIMUM SINGLE WINDING AND 220.0 OHMS MAXIMUM SINGLE WINDING" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 3C" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC INDUCTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC MOTOR LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES DC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC" |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTACTOR 60 AMP" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ENERGIZING ELEMENT AND CONTACTS" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-6106 GOVERNMENT SPECIFICATION" |
ABHP | OVERALL LENGTH | 3.130 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ADAV | OVERALL DIAMETER | 2.500 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.168 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.175 INCHES MAXIMUM SINGLE MOUNTING FACILITY" |
AGAV | END ITEM IDENTIFICATION | ALOFTS SONAR SYSTEM, MODEL 980 (V1)" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNA | WINDING DC RESISTANCE RATING | 180.0 OHMS MINIMUM SINGLE WINDING AND 220.0 OHMS MAXIMUM SINGLE WINDING" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 3C" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC INDUCTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC MOTOR LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES DC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC" |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTACTOR 60 AMP" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ENERGIZING ELEMENT AND CONTACTS" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-6106 GOVERNMENT SPECIFICATION" |